Specify The System
         
     

Option LG6 - Electroluminescent (EL) Low Level Exit Sign
         
   

The preparation in the door includes an electric hinge preparation, face hole located at 11” from bottom of door and centered in door width, and a wire harness between face hole and hinge preparation. If this option is used in conjunction with an electroluminescent frame option, the appropriate LiteGuide™ frame option (1-4) and ElectroLynx™ frame options must be selected when ordering frames.

Standard features included in the Option
(Price Add covers these features):

Door

  • 22 Gauge two conductor wire harness with quick connect connectors compatible with LiteGuide Power Supply
  • Door face hole punch
  • Electric hinge preparation

Product Offering:

  • Ceco: Legion, Regent, Medallion, Imperial, RestrictDor
  • Curries: 707, 727, 747, 847 door construction
  • Fleming: D, TRR, H, S, E door construction
  • No embossed panel doors
  • 1-3/4” or 2” thick door
  • 4-1/2” or 5” hinges
  • Bottom of vision kit must be greater than 20” from bottom of door

Optional Accessories:

  • Electroluminescent Exit Sign with LiteGuide power supply (NOTE: McKinney ‘MM’ hinge not compatible)
  • Order door and frame hinge preparation for McKinney ElectroLynx for compatible connection with wiring harness in door
  • ElectroLynx frame option can be ordered for quick connection to building wire via junction box in the head
  • McKinney QC4A electric hinge

Components and Who Supplies:

  • Hollow Metal door assembly: Hollow Metal Distributor
  • Electroluminescent Exit Sign with LiteGuide power supply: Hollow Metal Distributor
  • Electric Hinge: Hardware Distributor
  • 24 Volt DC, 2 Amp Regulated Power Supply for exit signs not powered by ELAP: Hardware Distributor.

Who Installs:

  • Contractor installs door.
  • Exit sign and Lite Guide Power Supply installed by contractor. Exit lighting contractor will connect exit sign to E-Lume-A-Path™ in E-Lume-A-Path™-powered systems.
  • Contractor is responsible for connecting power from other power supplies.
Suggested Architectural Specification – Option LG6
(Include paragraph in 08110 under "Part 2 - Products")

2.05 Electroluminescent Low Level Exit Signs

A. Provide designated hollow metal doors prepared for electroluminescent low level exit signs. These doors shall include:

  1. 22 Gauge two conductor wire harness with quick connect connectors compatible with LiteGuide 24 volt AC/DC to 170 volt AC power supply.
  2. Door face hole punch at 11” from bottom of door and centered in door width.
B. Provide electroluminescent exit sign for installation in each designated hollow metal door.

(Note to specifier: The appropriate LiteGuide frame option (LG1-LG4) and ElectroLynx frame options must be selected when specifying frames.)

 
SYSTEM PARTNERS

Trust the quality and integrity of door and hardware brands you have known for over 150 years.

 
 
MEDIA


Stay up to date on product launches, building projects and the LiteGuide System and its partners in the media.

 
 
CODE CORNER

Read about the new IBC requirement for luminous markings in vertical exit enclosures and exit passageways in buildings greater than 75 feet in height.

 
 

 

© Copyright 2008 ASSA ABLOY, Inc. All Rights Reserved.